The Laser PM Sensor MPM12-BG stands as a cutting-edge solution for precise particulate matter (PM) detection, featuring strategically positioned air inlets and outlets on the front. With a GH1.25mm connector, this sensor ensures optimal air sampling and seamless connectivity for precise data acquisition.
Designed to monitor PM1.0, PM2.5, and PM10 particles, the MPM12-BG delivers a comprehensive assessment of particulate matter concentrations in the air. The front-mounted air inlets and outlets enhance adaptability to diverse monitoring environments, making it versatile for various applications.
This sensor boasts high detection accuracy, with a tolerance of ±15μg/m³ or ±15% reading under standard conditions (at 25±2℃, 50%±10%RH). Its efficient power-on settling time of less than 10 seconds ensures a swift response and real-time data acquisition.
Compact and robust, the MPM12-BG is engineered for durability and versatility, making it suitable for environmental monitoring, industrial processes, and research initiatives. By providing accurate and real-time data, the MPM12-BG significantly contributes to enhanced air quality awareness and supports pollution control efforts, fostering healthier and more sustainable living environments.
Features:
- There are different types of particle detection, including PM1.0, PM2.5, and PM10.
- The particle detection diameter range for this system is 0.3 to 10 micrometers.
- The particulate matter concentration range, specifically for PM2.5 according to standard values, spans from 0 to 1000 micrograms per cubic meter (μg/m3).
- The Particle Mass Concentration Resolution achieved by the system is 1 μg/m3.
- Consistency in particulate matter concentration within the PM2.5 standard value exhibits a tolerance of ±10% for concentrations between 100 and 500 μg/m3, and ±10 μg/m3 for concentrations ranging from 0 to 100 μg/m3.
- The single response time of the system is remarkably swift, taking less than 1 second to provide accurate readings.
- The data interface level is specified as follows:
- For a low level (L), it should be less than 0.8 volts when operating at 3.3 volts.
- For a high level (H), it should be greater than 2.7 volts when operating at 3.3 volts.
Package Includes:
1 x MemsFrontier Laser PM sensor(Air inlet and outlet are on the front, GH1.25mmconnector)-MPM12-BG
There are no reviews yet.