The Laser PM Sensor MPM14-CS represents a cutting-edge solution for precise particulate matter (PM) detection, distinguished by its unique design with air inlets and outlets strategically positioned on opposite sides. With an 8-pin configuration, this sensor ensures seamless connectivity, enabling easy integration into air quality monitoring systems with detailed data output.
Engineered to monitor PM1.0, PM2.5, and PM10 particles, the MPM14-CS provides a comprehensive assessment of particulate matter concentrations in the air. The placement of air inlets and outlets on opposite sides enhances adaptability to diverse monitoring environments, making it versatile for various applications.
This sensor achieves high detection accuracy, with a tolerance of ±15μg/m³ or ±15% reading under standard conditions (at 25±2℃, 50%±10%RH). Its efficient power-on settling time of less than 10 seconds ensures rapid response and real-time data acquisition.
Compact and robust, the MPM14-CS is engineered for durability and versatility. It finds applications in environmental monitoring, industrial processes, and research initiatives. By providing accurate and real-time data, the MPM14-CS significantly contributes to enhanced air quality awareness and supports pollution control efforts, promoting healthier and more sustainable living environments.
Features:
- There are different types of particle detection, including PM1.0, PM2.5, and PM10.
- The particle detection diameter range for this system is 0.3 to 10 micrometers.
- The particulate matter concentration range, specifically for PM2.5 according to standard values, spans from 0 to 1000 micrograms per cubic meter (μg/m3).
- The Particle Mass Concentration Resolution achieved by the system is 1 μg/m3.
- Consistency in particulate matter concentration within the PM2.5 standard value exhibits a tolerance of ±10% for concentrations between 100 and 500 μg/m3, and ±10 μg/m3 for concentrations ranging from 0 to 100 μg/m3.
- The single response time of the system is remarkably swift, taking less than 1 second to provide accurate readings.
- The data interface level is specified as follows:
- For a low level (L), it should be less than 0.8 volts when operating at 3.3 volts.
- For a high level (H), it should be greater than 2.7 volts when operating at 3.3 volts.
Package Includes:
1 x MemsFrontier Laser PM sensor(The air inlet and outlet are located on opposite sides,8 pin)-MPM14-CS